1.
J Arrhythm ; 37(6): 1522-1531, 2021 Dec.
Article in English | MEDLINE | ID: covidwho-1437059

ABSTRACT

BACKGROUND: Transvenous lead extraction (TLE) for implantable cardiac-devices is traditionally performed under general anesthesia (GA). This can lead to greater risk of exposure to COVID-19, longer recovery-times and increased procedural-costs. We report the feasibility/safety of TLE using conscious-sedation alone with immediate GA/cardiac-surgery back-up if needed. METHODS: Retrospective case-series of consecutive TLEs performed using conscious-sedation alone between March 2016 and December 2019. All were performed in the electrophysiology-laboratory using intravenous Fentanyl, Midazolam/Diazepam with a stepwise approach using locking-stylets/cutting-sheaths, including mechanical-sheaths. Baseline patient-characteristics, procedural-details and TLE outcomes (including procedure-related complications/death) were recorded. RESULTS: A total of 130 leads were targeted in 54 patients, mean age ± SD 74.6 ± 11.8years, 47(87%) males; dual-chamber pacemakers (n = 26; 48%), cardiac resynchronization therapy-defibrillators (n = 17; 31%) and defibrillators (n = 8; 15%) were commonest extracted devices. Mean ± SD/median (range) lead-dwell times were 11.0 ± 8.8/8.3 (0.3-37) years, respectively. Extraction indications included systemic infection (n = 23; 43%) and lead/pulse-generator erosion (n = 27; 50%); mean 2.1 ± 2.0 leads were removed per procedure/mean procedure-time was 100 ± 54 min. Local anesthetic (LA) was used for all (mean-dose: 33 ± 8 ml 1% lidocaine), IV drug-doses used (mean ± SD) were: midazolam: 3.95 ± 2.44 mg, diazepam: 4.69 ± 0.89 mg and fentanyl: 57 ± 40 µg. Complete lead-extraction was achieved in 110 (85%) leads, partial lead-extraction (<4 cm-fragment remaining) in 5 (4%) leads. Sedation-related hypotension requiring IV fluids occurred in 2 (managed without adverse-consequences) and hypoxia requiring additional airway-management in none. No procedural deaths occurred, one patient required emergency cardiac surgery for localized ventricular perforation, nine had minor complications (transient hypotension/bradycardia/pericardial effusion not requiring intervention). CONCLUSION: TLE undertaken using LA/conscious-sedation was safe/feasible in our series and associated with good clinical outcome/low procedural complications. Reduced risk of aerosolization of COVID-19 and quicker patient recovery/reduced anesthetic risk are potential benefits that warrant further study.

2.
Int J Cardiol ; 322: 170-174, 2021 01 01.
Article in English | MEDLINE | ID: covidwho-799320

ABSTRACT

BACKGROUND: Catheter ablation for complex left-atrial arrhythmia is increasing worldwide with many centres admitting patients overnight. Same-day procedures using conscious sedation carry significant benefits to patients/healthcare providers but data are limited. We evaluated the safety and cost-effectiveness of same-day complex left-atrial arrhythmia ablation. METHOD: Multi-centre retrospective cohort study of all consecutive complex elective left-atrial ablation procedures performed between January 2011 and December 2019. Data were collected on planned same-day discharge versus overnight stay, baseline parameters, procedure details/success, ablation technology, post-operative complications, unplanned overnight admissions/outcomes at 4-months and mortality up to April 2020. A cost analysis of potential savings was also performed. RESULTS: A total of 967 consecutive patients underwent complex left-ablation using radiofrequency (point-by-point ablation aided by 3D-mapping or PVAC catheter ablation with fluoroscopic screening) or cryoballoon-ablation (mean age: 60.9 ± 11.6 years, range 23-83 yrs., 572 [59%] females). The majority of patients had isolation of pulmonary veins alone (n = 846, 87%) and most using conscious-sedation alone (n = 921, 95%). Of the total cohort, 414 (43%) had planned same-day procedure with 35 (8%) admitted overnight due to major (n = 5) or minor (n = 30) complications. Overall acute procedural success-rate was 96% (n = 932). Complications in planned overnight-stay/same-day cohorts were low. At 4-month follow-up there were 62 (6.4%) readmissions (femoral haematomas, palpitation, other reasons); there were 3 deaths at mean follow-up of 42.0 ± 27.6 months, none related to the procedure. Overnight stay costs £350; the same-day ablation policy over this period would have saved £310,450. CONCLUSIONS: Same-day complex left-atrial catheter ablation using conscious sedation is safe and cost-effective with significant benefits for patients and healthcare providers. This is especially important in the current financial climate and Covid-19 pandemic.


Subject(s)
Ambulatory Surgical Procedures/economics , Arrhythmias, Cardiac/surgery , Catheter Ablation/economics , Cost-Benefit Analysis , Adult , Aged , Aged, 80 and over , Ambulatory Surgical Procedures/adverse effects , Catheter Ablation/adverse effects , Cohort Studies , Female , Heart Atria/surgery , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL